Orthopedic Surgical Veterinary Equipment (System8200)

Customization: Available
Type: Diagnosis & Injection
for Animal: Pets

Product Description

📋 Basic Information
Model NO.
BJ8200
Dosage Form
Power Tool
Function
Trauma Surgery
Main Material
Stainless Steel, Aluminium Alloy
Name
Orthopedic Drill for Small Animal
Color
Slivery
Application
Use of Trauma Operation
Certificate
CE, FDA, ISO
Packing
Carton or Sterilized Case
Voltage
7.2V
HS Code
90189090
Production Capacity
20000 Sets/Year
🖼️ Product Display
⚙️ Technical Specifications
Electric HandpieceBJ8200
Weight (with battery)≤1000 Grams
Speed Range0-15000 rpm
Power SourceBattery (Ni-Mh Technology)
SterilizableAutoclavable
Sterilization Temperature135°C
Noise Level≤45 db
Sagittal Saw AttachmentBJ8201
Oscillations0-15000 osc/min
Bone Drill AttachmentBJ8202
Speed0-1100 r.p.m
Torque0.9 Nm
Canulate Drill AttachmentBJ8203
Speed0-460 r.p.m
Torque1 Nm
K-wire Drill AttachmentBJ8213
Speed0-1100 r.p.m
Torque1 Nm
⚠️ Operation Notes
01Sterilize temperature must be ≤ 135 °C. Exceeding this will damage the motor.
02Normal bone drills hold bits < 6mm. Acetabulum reaming drills operate at ~300 rpm, and canulate drills at ~600 rpm.
03Remove the battery immediately after surgery to prevent automatic discharge and shorten battery life.
04The battery is NOT autoclavable and cannot be sterilized.
05The cranial bur must be washed and dried immediately after surgery to avoid blood sticking.
06Ensure no water remains in the battery space of the handpiece after sterilization.
❓ Frequently Asked Questions
What is the main material used in the BJ8200 drill?
The device is primarily constructed from high-quality Stainless Steel and Aluminium Alloy for durability and hygiene.
Can the entire unit be put in an autoclave?
The handpiece and attachments are autoclavable up to 135°C. However, the battery is NOT autoclavable and must be removed before sterilization.
How long does the battery last during continuous use?
The Ni-Mh battery provides a run time of approximately 30-40 minutes on a full charge.
What is the maximum speed of the sagittal saw attachment?
The sagittal saw (BJ8201) can reach oscillations between 0 to 15,000 osc/min.
Is this equipment suitable for small animal trauma surgery?
Yes, it is specifically designed as an orthopedic drill for small animals and is suitable for various trauma operations.
What are the noise levels of the attachments?
The noise level is kept low for surgical environments, generally ranging between ≤40db and ≤45db depending on the attachment used.

Related Products