Hospital Respiratory Breathing Veterinary Animal Anesthesia Ventilator Machine Equipment Workstation

Still deciding? Get samples of $ !
Request Sample

Product Description

📊 Basic Information
Model NO.
CWH-1010
Usage
Pet Care
Animal
Cat, Dog, Sheep, Horse
Ventilation Mode
Ippv, Simv, Manual(Bag)
Warranty
1 Year
Safety Valve Pressure
6kpa
Transport Package
Carton Package
Specification
10kg
Origin
China
CWH-1010 Anesthesia Ventilator
⚙️ Main Specifications
Electronically controlled, pneumatic driven
Patient spectrum: pediatric to bariatric
Ventilation mode: IPPV, SIMV, MANUAL(BAG)
Tidal volume: Adjustment range 0-1500ml
I:E ratio: 4:1-1:8
Frequency range: 1-100bpm
IPPV and Manual mode: 4~65bpm
SIMV mode: 1-40bpm
Monitoring: VT, MV, BPM, Paw, FiO2, PEEP
Waveforms: Pressure-time, Flow-time
Power: AC 220V, built-in battery > 2hrs
Inspiratory time (TI): 0.2s - 6.0s
Pressure trigger: -20 cmH2O ~ + 20 cmH2O
Safety valve pressure limit: 6Kpa
Alarms: High/Low pressure, MV, AC power loss
📷 Product Gallery
CWH-1010 Anesthesia Ventilator View 1
CWH-1010 Anesthesia Ventilator View 2
CWH-1010 Anesthesia Ventilator View 3
CWH-1010 Anesthesia Ventilator Details
CWH-1010 Anesthesia Ventilator Interface
CWH-1010 Anesthesia Ventilator Components
CWH-1010 Anesthesia Ventilator Workstation
❓ Frequently Asked Questions
Which animals can use the CWH-1010 Anesthesia Ventilator?
The CWH-1010 is versatile and designed for veterinary use on a wide range of animals, including cats, dogs, sheep, and horses.
What ventilation modes does this equipment support?
It supports three main ventilation modes: IPPV (Intermittent Positive Pressure Ventilation), SIMV (Synchronized Intermittent Mandatory Ventilation), and MANUAL (Bag) mode.
Does the ventilator have a backup battery for power emergencies?
Yes, it features a built-in rechargeable 12V battery that provides more than 2 hours of operation in case of AC power loss.
What is the tidal volume adjustment range?
The tidal volume can be adjusted from 0 to 1500ml, making it suitable for patients ranging from pediatric to bariatric sizes.
How does the alarm system ensure patient safety?
The device includes multiple safety alarms, such as High/Low airway pressure alarms, High/Low Minute Volume (MV) alarms, and an AC power loss alarm to ensure continuous monitoring.
What parameters can be monitored on the display?
Real-time monitoring includes Tidal Volume (VT), Minute Volume (MV), Breaths Per Minute (BPM), Airway Pressure (Paw), FiO2, PEEP, I:E ratio, and peak pressure (Ppeak), along with pressure-time and flow-time waveforms.